Follow Us:
Item No.
HT022
Item Name.

Hantek dso8202e 2 Channels 200Mhz Digital Oscilloscope 1GS/s Sample Rate 2M Memory Depth Portable Handheld Osciloscopio

Item Price:
USD
USD$780.00
Weight
2.5kg
Quantity:
100 PCS in stock now!
-
+
Note: Please Select the Frequency and Chip Type
  • Products Description
  • Reviews
Hantek dso8202e 2 Channels 200Mhz Digital Oscilloscope 1GS/s Sample Rate 2M Memory Depth Portable Handheld Osciloscopio




 

Hantek DSO8202E Digital Osciloscopio USB PC Based Storage Lcd Automotive Oscilloscope Portable Multimeter 200Mhz 2 Channels Diagnostic-tool

 

DSO8000E Series

Six in one: Oscilloscope/Recorder/DMM/ Spectrum Analyzer/Frequency Counter/Arbitrary Waveform generator. IP-51 rated for dust, drip and shake proof to withstand harsh environments. Large fuse confirms to European Safety Standard. Battery indicator with easy-changed connect points. Selectable 18650 battery box for matching 18650 battery by yourself. Anti-theft lock hole, tripod fixed hole, hang rope, FLASH light that can be used in darkness. Replaceable BNC safety joints, and additional one set of joints. 1GSa/s sample rate, 2M Memory depth, 6000 counts DMM. Large 5.6 inch TFT Color LCD Display; High Resolution(640*480)

-features

* Six in one: Oscilloscope/Recorder/DMM/ Spectrum Analyzer/Frequency Counter/Arbitrary Waveform generator.

* IP-51 rated for dust, drip and shake proof to withstand harsh environments.

* Large fuse confirms to European Safety Standard.

* Battery indicator with easy-changed connect points. Selectable 18650 battery box for matching 18650 battery by yourself.

* Anti-theft lock hole, tripod fixed hole, hang rope, FLASH light that can be used in darkness.

* Replaceable BNC safety joints, and additional one set of joints.

* High bandwidth 70MHz-200MHz Oscilloscope, 1GSa/s sample rate, 2M Memory depth.

* 25Mz Arb. Waveform Generator, 200 Mesa/s DDS, 12 bit vertical resolution, easy for simulating transducer

* 6000 Counts DMM, AC/DC voltage, AC/DC current, resistance, break, capacitance, and diode function.

* FFT spectral analysis; Waveform Math: add, subtract, multiply and divide; X-Y mode; more than 20 automatic measurements; PASS/FAIL Check function, apply to engineering application.

* Abundant trigger function, double timebase sampling, easy to observe two waveforms in different frequency.

* Record and replay of more than 1000 waveforms.

* Large 5.6 inch TFT Color LCD Display; High Resolution(640*480)

* USB Host/Device 2.0 full-speed interface; support removable disk; WIFI/LAN Option, easy to control by PC or long-distance.

* Waveform data can be output in WORD,EXCEL, BMP, JPG as time and voltage.

-Specifications

Model DSO8072E DSO8102E DSO8152E DSO8202E
Acquisition
Sample Modes Real-Time Sample
Acquisition Modes  
Normal Normal data only
Peak Detect High-frequency and randon glith capture
Average Wavefom Average, selectable 4,8,16,32,64,128
Inputs
Inputs Coupling AC, DC, GND
Inputs Impendance 1M2% 20pF3pF
Probe Attenuation 1X, 10X
Supported Probe Attenuation Factor 1X, 10X, 100X, 1000X
Maximum Input Voltage CAT I and CAT II: 300VRMS (10×), Installation Category;
CAT III: 150VRMS (1×)
Horizontal System
Sample Rate Range 1GS/s
Waveform Interpolation (sin x)/x
Record Length 2M
SEC/DIV Range 4ns/div~2000s/div, in a 2, 4, 8 sequence 2ns/div~2000s/div, in a 2, 4, 8 sequence
Sample Rate and
Delay Time Accuracy
50ppm over any 1ms time interval
Scanning Speed Range 4ns/div to 8ns/div; (-8div x s/div) to 40ms;
20ns/div to 80s/div;(-8div×s/div) to 40ms;
200s/div to 40s/div;(-8div×s/div) to 400s;
2ns/div to10ns/div;(-4div×s/div) to 20ms;
Delta Time Measurement Accuracy 
(Full Bandwidth)
Single-shot, Normal mode: (1 sample interval +100ppm × reading + 0.6ns);
>16 averages: (1 sample interval + 100ppm × reading + 0.4ns);
Sample interval = s/div ÷ 200
Vertical System
Vertical Resolution 8-bit resolution, all channel sampled simultaneously
Volts Range 2mV/div to 100V/div at input BNC
Bandwidth 70MHz 100MHz 150MHz 200MHz
Rise Time at BNC( typical) 5ns 3.5ns 2.3ns 1.8ns
Analog Bandwidth in
Normal and Average
modes at BNC or with probe, 
DC Coupled
400V(100V/div-20V/div); 
50V(10V/div-5V/div);
40V(2V/div-500mV/div); 
2V(200mV/div-50mV/div);
400mV(20mV/div-2mV/div);
Math +, -, *, /, FFT
FFT Windows: Hanning, Flatop, Rectamgular, Bartlett, Blackman; 1024 sample point
Bandwidth Limit 20MHz
Low Frequency Response (-3db) 10Hz at BNC
DC Gain Accuracy 3% for Normal or Average acquisition mode, 100V/div to 10mV/div.
4% for Normal or Average acquisition mode, 5mV/div to 2mV/div.
DC Measurement Accuracy, 
Average Acquisition Mode
Measurement Type: Average of 16 waveforms with vertical position at zero
Accuracy: (3% × reading + 0.1div + 1mV) when 10mV/div or greater is selected.
Measurement Type: Average of 16 waveforms with vertical position not at zero
Accuracy: [3% × (reading + vertical position) + 1% of vertical position + 0.2div].
Volts Measurement Repeatability, 
Average Acquisition Mode
Delta volts between any two averages of 16 waveforms acquired under same setup and ambient conditions
Trigger System
Trigger Types Edge, Video, Pulse, Slope, Over time, Alternative
Trigger Source CH1, CH2, AC Line
Trigger Modes Auto, Normal, Single
Coupling Type DC, AC, HF Reject, LF Reject, Noise Reject
Trigger Sensitivity
(Edge Trigger Type)
DC(CH1,CH2):
1div from DC to 10MHz; 1.5div from 10MHz to 100MHz; 2div from 100MHz to Full;
AC: Attenuates signals below 10Hz ;
HF Reject: Attenuates signals above 80kHz;
LF Reject: Same as the DC-coupled limits for frequencies above 150kHz; attenuates signals below 150kHz.
Trigger Level Range CH1/CH2: 8 divisions from center of screen;
Trigger Level Accuracy( typical)Accuracy is for signals having rise and fall times 20ns CH1/CH2: 0.2div × volts/div within 4 divisions from center of screen;
Set Level to 50%(typical) Operates with input signals 50Hz
Video Trigger  
Video Trigger Type CH1, CH2: Peak-to-peak amplitude of 2 divisions;
Signal Formats and Field Rates Supports NTSC, PAL and SECAM broadcast systems for any field or any line
Holdoff Range 100ns ~ 10s
Pulse Width Trigger  
Pulse Width Trigger Mode Trigger when (< , >, = , or ); Positive pulse or Negative pulse
Pulse Width Trigger Point Equal: The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level.
Not Equal: If the pulse is narrower than the specified width, the trigger point is the trailing edge. Otherwise, the oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width.
Less than: The trigger point is the trailing edge.
Greater than (also called overtime trigger): The oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width
Pulse Width Range 20ns ~ 10s
Slope Trigger  
Slope Trigger Mode Trigger when (< , > , = , or ); Positive slope or Negative slope
Slope Trigger Point Equal: The oscilloscope triggers when the waveform slope is equal to the set slope.
Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope.
Less than: The oscilloscope triggers when the waveform slope is less than the set slope.
Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope.
Time Range 20ns ~ 10s
Overtime Trigger  
Over Time Modee Rising edge or Falling edge
Time Range 20ns ~ 10s
Alternative Trigger  
Trigger on CH1 Internal Trigger: Edge, Pulse Width, Video, Slope
Trigger on CH2 Internal Trigger: Edge, Pulse Width, Video, Slope
Trigger Frequency Counter  
Readout Resolution 6 digits
Accuracy (typical) 30ppm (including all frequency reference errors and 1 count errors)
Frequency Range AC coupled, from 4Hz minimum to rated bandwidth
Signal Source Pulse Width or Edge Trigger modes: all available trigger sources
The Frequency Counter measures trigger source at all times, including when the oscilloscope acquisition pauses due to changes in the run status, or acquisition of a single shot event has completed.
Pulse Width Trigger mode: The oscilloscope counts pulses of significant magnitude inside the 1s measurement window that qualify as triggerable events, such as narrow pulses in a PWM pulse train if set to < mode and the width is set to a relatively small time.
Edge Trigger mode: The oscilloscope counts all edges of sufficient magnitude and correct polarity.
Video Trigger mode: The Frequency Counter does not work.
Measure
Cursor Measurement Manual: Voltage difference between cursors: V
Time difference between cursors: T
Reciprocal of T in Hertz (1/T);
Tracing: The valtage and time at a waveform point;
Auto Measuerment Frequency, Period, Mean, Pk-Pk, Cycli RMS, Minimum, Maximum, Rise time, Fall Time, +Pulse Width, -Pulse Width, Delay1-2Rise, Delay1-2Fall, +Duty, -Duty, Vbase, Vtop, Vmid, Vamp, Overshoot, Preshoot, Preiod Mean, Preiod RMS,
Waveform Generator Mode
Frenquency Range 1Hz(DC)~25MHz
DAC Clock 2K~200MHz adjustable
Memory Depth 4KSa
Vertical Resolution 12 Bits
Stability <30ppm
Amplitude 3.5V Max.
Output Impedance 50
Output Current 50mA Ipeak=50mA
System Bandwidth 25M
Harmonic Wave Distortion -50dBc(1KHz), -40dBc(10KHz)
General Specifications
Display Resolution 640 horizontal by 480 vertical pixels
Display Contrast Adjustable (16 gears) with the progress bar
Probe Compensator Output  
Output Voltage( typical) About 2Vpp into 1M load
Frequency(typical) 1kHz
Power Supply  
Supply Voltage AC Input:100-240VACRMS,0.6A MAX,50Hz~60Hz; DC Output:9V,2A
Power Consumption <30W
Environmental  
Temperature Operating: 32F to 122F (0C to 50C);
Nonoperating: -40F to 159.8F (-40C to +71C)
Cooling Method Convection
Humidity +104F or below (+40C or below): 90% relative humidity;
106F to 122F (+41C to 50C): 60% relative humidity
Altitude Operating: Below 3,000m (10,000 feet);
Nonoperaring: Below 15,000m(50,000 feet)
Mechanical  
Size 260mmmm; 220mm; 75mm
Weight 2.5KG(without Packing)

1

2


-package including

3

1

Average rating: 5.0
Share your thoughts with other customers
Write a review
Product reviews can be carried out after the member login, please click here to login